вторник, 12 июля 2011 г.

The valve controls the air supply system

The valve controls the air supply system (4A-GE (AE92) without flow excitation ¬ spirit release since 1989)
Circuit of the valve control system air supply. 1 - ak-kumulyatornaya battery, 2 - the main fuse "AT" (100A)
3 - fuse "AMS" (40A)
4 - ignition, 5 - valve system administration topics ¬ air inlet, 6 - from the main relay system vpry ¬ ska fuel, 7 - electronic control unit.
1. Use an ohmmeter to make sure you have the conductivity of the winding circuit valve, measuring the resistance ofthe IU ¬ forward to the conclusions of its socket.
Rated
resistance 20 - 26 ohms
If the resistance value exceeds the specified limits, replace the valve.
2. Using an ohmmeter, check the resistance between each terminal connector valve and its casing, Ube-divshis in the absence of breakdown of the windings to ground.
If the ohmmeter registers any resistance other than infinity, replace the valve control system air supply. 3 Check the operation of the valve control system air supply.
b) Place the power accumulators ¬ reflex battery to the conclusions of the valve.
c) Ensure that the air passes from the channel "E" channel "P".
a) Make sure that air does not pass between the channels DIT ¬ "E" and "P" in the absence of voltage on the coil valve.
If the valve does not operate on the principle described Nome, then replace the valve control system air supply.
Conditioning system off ¬ tsionera (4A-FE (AE111), 5A-FE (AE110), 7A-FE (AE115))
This system is used for switching off of the air conditioner ¬ if one of the following conditions:
a) Start the engine.
b) drive off.
c) The acceleration from 40 km / h at 2800 rev / min.
1. Check the voltage, a) Turn the ignition key. B) Measure the voltage between you vodom ¬ "AST connector and the electronic control unit mass when the air conditioner. .9 Rated voltage - 14 V
1 - Input, 2 and 7 - bearings, 3 - electric anchor, 4 - pressure-reducing valve, 5 - output, 6 - reverse cluster-pan, 8 - Magnet, 9 - rotor (wing ¬ Chatka), 10 - the pump casing.
Fuel pump (circuit connected ¬ radiation). (4A-GE (AE92 and AT160 ¬ you start with 1987)). 1 - accumulators ¬ trodden battery, 2, 3, 4, 5 - fuses: 0.85V, "AM2" (30A), "AT" (80A), "AM1" (40A), 6 - Tel fuse ¬ "EP1" (15A), 7 - lock of ignition, 8 - fuse "YM" (10A (AE) and 7.5 A (AT)), 9 - the main relay fuel injection system, 10 - relay-switch fuel pump
11 - Diagnostic connector
Fuel Pump
12 - fuel pump, 13 - relay then ¬ plivnogo pump, 14 - meter air (air flow meter model), 15 - to the electronic control unit (model without spending ¬ measure of air).
Wiring diagram for fuel pump (4A-FE (AE101), 7A-FE (AE102)). 1 - Battery 2 - the main fuse 3.0I, 3 - fuse "AM2" (30A), 4 and 5 - fuses, "AM1" (40A) and "AN" (100A), 6 - fuse "EP1" (15A), 7 - ignition, 8 - fuse! "0M" (10A), 9 - the main relay systems ¬ themes injection, a 10-diagnostic connector, 11 - relay switch the fuel pump, 12 - the fuel for ¬ wc, 13 - to the electronic control unit, 14 - ¬ you klyuchatel prohibit launch.
Wiring diagram for fuel pump (4A-FE (AE92, AE95, AT171 and AT180) 4A-GE (AE92, produced after 1987), 7A-FE (AE93)). 1 - Battery, 2 and 3 - the main fuses 2.0 and 0.85, 4, 5,
6 - fuses: AM2 (30A), AM1 (40A for the AE92, AE95, AE93 and AT180 and AT171 for 60A), AN (100A for AE92, AE95, AE93 and AT180 and AT171 for 80A), 3 and
7 - EP fuse! (15A), 8 - ignition, 9 - fuse! CM (10A for the AE92, AE95, AE93 and 7.5 A for AT171, AT180) 10 - the main relay fuel injection system, 11 - diagnostic connector, 12 - relay-switch fuel pump 13 - fuel pump, 14 - Relay top ¬ tidal pump (air flow), the 15 models with flow of air, 16 - to the electronic control unit (for models without air flow meter), 17 - switch prohibiting launch.
Wiring diagram for fuel pump (4A-FE (AT190)). 1 - Battery 2 - the main fuse 2.01, 3 - AM2 fuse (30A), 6 - Fuse EP! (15A), 7 - ignition, 8 - fuse! CM 7.5a, 9 - the main relay fuel injection system, a 10-diagnostic-optical connector, 11 - relay-switch fuel pump ¬ sa, 12 - fuel pump, 13 - by e-mail control unit, 14 - fuel pump relay, 15 - fuse fuse starter ¬ 8T (7.5 A).

Комментариев нет: